Modifications and Services |
|
With a CSA & EASA certified repair/modification facility in Edmonton, we offer various services as follows: - Most motor & pump repairs and refurbishing
- On-site and in-house troubleshooting
- Applications specific modifications
- Vibration analysis
- Instrumentation installations
- XP mods and repairs
- Recip compressor spciatly mods and data retrival
- Accessory re-design and custom build
- Field Services
Special Service Supply and Modification Examples: Encana, Inga Site (BC) / Enerflux, Lakusta reciprocating compressor application. We imported a new stocked 60hp, 1200rpm, 4160V, WPII, Teco Motor and performed the following modifications: - Replaced the shaft with 4140 steel, keyless version
- Supplied the Shaft profile from the replacement with tensile and yeild data for torsional analysis
- The new shaft was specified with machined steps at 0.05"
- Replaced bearing & Stator RTD's with Type J thermocouples
- Replaced 300W spave heater with 200W for Div 2 Atmoshere
- Special epxoy coated Cu bar Rotor and Tinned the leads for H2S service
- Supplied a 4160V, Nema 12 Motortronics Soft Starter
- All the above was performed and delivered in 10 working days for the date of PO to the compressor OEM.
- The overall costs were competitivedespite the fact that they were stock items
Continental Motors of New Jersey manufactured and delivered the following within 6 weeks of receipt of the order: - Quantity 2
- 600 hps
- TEXP
- 7200 V
- 900rpm
- 1.15 SF
- Cast Iron Frames
- Standard Accessories (BTD's, STD's, S.H.)
- Precision Balance
- Copper Bar Rotor
CNRL, Primrose Site CNRL had THIRTY new Siemens motors to be special modified for 4:1 CT VFD Turndown. No kits were available so we performed the following: - Analysis of the Air flow required to cool the motor properly while maintaining the T-code for the Div 2 area.
- Design and special build a fan shroud extension with mounting solutions sensitive to fragile grill strength.
- Source and manufacture 30 of a special pitched non-sparking aluminium fans.
- With a reduced HP for weight considerations, supply 30 XP, 3ph, 575V, 56C frame, 1 HP Marathon Motors.
- Design and special build 30 non-sparking aluminium shaft extensions for the Blower motors.
- Match the Siemens paint, mount and test run all 30 kits on site.
- The CNRL Primrose site requires unique staff insurance levels and orientation due to the military location.
- All the above was performed and concluded within 6 weeks pf receipt of order.
|